Compared with the traditional probe , MVE1998-30.4 center pin has a correction function,
which can solve the tolerance of antenna connectors on the board when the fixture is work.
Effectively improve test stability and reduce retest rate.


According to the test results,we can know the S21 flatness<0.1dB at the same frequency by testing 5pc MVE1998-30.4 at random.
 
S21(dB) AC 40MHz AX 80MHz AX 160MHz
Mhz 2422 2442 2462 5210 5290 5530 5690 5775 5250 5570
MVE1998-30.4_1 0.167 0.172 0.163 0.131 0.124 0.163 0.171 0.168 0.126 0.171
MVE1998-30.4_2 0.174 0.18 0.17 0.077 0.076 0.152 0.158 0.157 0.072 0.157
MVE1998-30.4_3 0.179 0.186 0.176 0.107 0.105 0.167 0.172 0.17 0.105 0.17
MVE1998-30.4_4 0.173 0.18 0.171 0.141 0.131 0.159 0.161 0.158 0.136 0.163
MVE1998-30.4_5 0.182 0.188 0.18 0.103 0.1 0.157 0.162 0.163 0.098 0.162